How To Replace The 9V backup Battery In A 240V Smoke Alarm

Shock your friends with this post.

Key Takeaways

  • The backup battery is a 9V: a 240V mains alarm has a 9V battery inside the alarm head, and it can be replaced.
  • Chirping means flat: an intermittent chirp usually means the backup battery needs replacing.
  • Sealed 10 year alarms are different: if the battery is not replaceable, the whole alarm must be replaced.
  • Test it afterwards: press and hold the test button once the alarm is back on the ceiling.

What Battery Does a 240V Smoke Alarm Use?

Jordan and Tate from Florance Electrical have another handy electrical tip. We are going to show you how to replace a 9V battery in your Brooks 240V smoke alarm. If you are wondering what battery for smoke alarm to buy, a mains powered alarm of this type takes a 9V backup battery.

It is important to know if the smoke alarms are working in your home or business, and equally important to replace the batteries yearly.

How to Replace the 9V Backup Battery in a 240V Smoke Alarm

This brand of smoke alarm is a little bit trickier than usual to replace the battery in. Rather than having a button on the side that simply depresses to allow access to the internal areas of the smoke alarm, Brooks smoke alarms have a flat slot on the side that needs a tool pressed into it to allow the smoke alarm to be pushed away and clip off of the ceiling.

Ideally a small flat head screwdriver should be used, but essentially anything that will fit the slot without damaging the smoke alarm is perfect, such as a butter knife, bobby pin or anything close by that fits. If your smoke alarm is chirping intermittently, typically this means that the smoke alarm has a flat 9V backup battery.

Press the flat tool into the side identified by a label stating this instruction, also identified by the small flat gap for the tool. Then follow these steps:

  1. Push the smoke alarm away from your person.
  2. Replace the battery with a new one and place it back into the battery compartment.
  3. Re-install the alarm in the opposite manner.
  4. Place it against the smoke alarm base and move towards your person, ensuring that the clips are lining up.

Another handy tip from Florance Electrical saving you time and money on calling an electrician for this task, which can be completed safely without any danger of touching live parts of the smoke alarm. If you are not sure, or the alarm is hardwired and needs more than a battery, see our guide on whether you need an electrician to replace hardwired smoke detectors.

When a Smoke Alarm Battery Cannot Be Replaced

Some brands of smoke alarms have a sealed lithium battery compartment. These smoke alarms cannot have the battery replaced and must be discarded, and a new smoke alarm installed, if they have a flat battery.

If the battery is not flat, a good way to determine if the alarm is still serviceable is to read the label on the side frame of the smoke alarm. It will indicate the year in which the battery will likely fail or expire and the smoke alarm must be replaced. Not sure which type you have? Read our guide on how to identify types of smoke alarms.

Frequently Asked Questions

What battery does a 240V smoke alarm take?

A mains powered 240V smoke alarm has a 9V backup battery inside the alarm head. Check the label on your alarm for the exact battery type, and replace the battery yearly.

Why is my 240V smoke alarm chirping?

An intermittent chirp usually means the 9V backup battery is flat. Release the alarm head from its base, replace the battery and refit the head. If it keeps chirping, the alarm may be at the end of its life.

Is it safe to change the battery in a hardwired smoke alarm?

Once the alarm head is off the ceiling base, the battery can be replaced without touching live parts. If you are unsure at any point, stop and call a licensed electrician.

What if my smoke alarm has a sealed 10 year battery?

A sealed lithium battery cannot be replaced. When it starts chirping or reaches the expiry year on the label, the whole alarm must be replaced.